  cint1200 200w single output industrial series www.slpower.com cint1200 rev 1.4 12-june-13 1 features  3? x 5? x 1.3? package  200w with 100lfm air  180w convection cooled  class b conducted emi  fits 1u applications  universal input 90-264 vac  approved to csa/en/iec/ul60950-1, 2 nd edition  efficiency 90% typical  3 year warranty  rohs compliant description a power-packed, highly efficient ac to dc power su pply designed for industrial and ite applications. these models provide 180 watts convection cooled, 200 watts with moving air. the small heat footprint allows simpl e thermal design of systems which use this product. all models are ce marked to low voltage directive and approved to ite standards of en60950-1, 2nd edition. model selection model output current minimum ripple & total ovp number volts w/1 00lfm air convection * load noise** regula tion threshold*** cint1200a1275k01 12v 16.7a 15.0a 0a 120mv pk-pk 3% 14.0 1.1v cint1200a1575k01 15v 13.3a 12.0a 0a 150mv pk-pk 3% 18.5 1.2v cint1200a1875k01 18v 11.1a 10.0a 0a 180mv pk-pk 3% 21.5 2.0v cint1200a2475k01 24v 8.33a 7.50a 0a 240mv pk-pk 3% 29.0 2.5v CINT1200A2875K01 28v 7.14a 6.40a 0a 280mv pk-pk 3% 33.5 2.5v cint1200a3275k01 32v 6.25a 5.62a 0a 320mv pk-pk 3% 36.0 3.0v cint1200a3675k01 36v 5.55a 5.00a 0a 360mv pk-pk 3% 41.0 3.0v cint1200a4875k01 48v 4.17a 3.75a 0a 480mv pk-pk 3% 56.0 3.0v notes: * total convection power is 180 watts. ** measured with noise probe directly across output terminals, and load terminated with 0.1 f ceramic and 10 f low esr capacitors. general specifications ac input 100-240vac, 10%, 47-63hz, 1 ? 120?370vdc turn on time less than 3 sec. @115vac, full load input current 115vac: 1.8a, 230vac: 0.9a hold-up time 16ms at 200w, 120vac/60hz
cint1200 200w single output industrial series www.slpower.com cint1200 rev 1.4 12-june-13 2 specifications (continued) inrush current 264vac, cold start: will not exceed 55a overtemperature protection sensing transformer temperature, 165c at full load, latching type, requires input power recycling to reset. input fuses f1, f2: 3.15a, 250vac fuses provided on all models overload protection 120 to 150% of rating, hiccup mode earth leakage current <500 a@264vac, 60hz, nc; <1ma sfc short circuit protection hiccup mode, auto recovery. efficiency 88% typical overvoltage protection ovp latch, see models chart for trip range. output power 200w continuous, with 100 lfm airflow, 180w convection cooled ? see chart for specific voltage model ratings. switching frequency pfc: fixed, 65khz main converter: variable 35-200khz, 65- 70khz at full load. transient response 500s typical, return to 0.5% of nominal, 50% load step. ? i/ ? t: <0.2a/ s. max voltage deviation = 3% isolation input-output: 4000vac input-ground: 1800vac output-ground: 1500vac ripple and noise 0.5%rms, 1% pk-pk, see chart. operating temperature -10c to +70c start up at -40c, full load output voltage see chart temperature derating derate output power linearly above 50c to 50% at 70c voltage adjustability fixed output storage temperature -40c to +85c minimum load not required altitude operating: -500 to 10,000 ft. non-operating: -500 to 40,000 ft. total regulation +/- 3% combined line, load and initial setting. relative humidity 5% to 95%, non-condensing vibration operating: 0.003g 2 /hz, 1.5grms overall, 3 axes, 10 min/axis non-operating: 0.026g 2 /hz, 5.0grms overall, 3 axes, 1 hr/axis shock operating: half-sine, 20gpk, 10ms, 3 axes, 6 shocks total non-operating: half-sine, 40 gpk, 10 ms, 3 axes, 6 shocks total dimensions w: 3.0? x l: 5.0? x h: 1.3? safety standards en/csa/ul/iec 60950-1, 2nd edition weight 325g mtbf 401,000 hours, 25 c, 110vac output vs. temperature derating curve 180w convection cooled and 200w continuous with 100 lfm airflow, derate output power to 50% at 70 c.
cint1200 200w single output industrial series www.slpower.com cint1200 rev 1.4 12-june-13 3 emi/emc compliance conducted emissions en55011/22 class b, fcc part 15, subpart b, class b radiated emissions en55011/22 class a, fcc part 15, subpart b, class a w/6db margin static discharge immunity en61000-4-2, 6kv contact discharge, 8kv air dischar ge radiated rf immunity en61000-4-3, 3v/m. eft/burst immunity en61000-4-4, 2kv/5khz line surge immunity en61000-4-5, 1kv differential, 2kv common-mode conducted rf immunity en61000-4-6, 3vrms power frequency magnetic field immunity en61000-4-8, 3a/m voltage dip immunity en61000-4-11, 100%, 10ms; 30%, 275ms; 60%, 100ms; p erformance criteria a, a, & a at 70% load. line harmonic emissions en61000-3-2, class a, b, c, & d flicker test en61000-3-3, complies (dmax<6%) mechanical drawing notes: 1. all dimensions in inches (mm), tolerance is +/-0.000?. 2. mounting holes should be grounded for emi purposes. 3. fg is safety ground connection. 4. the power supply requires mounting on metal standoffs 0.20? (5mm) in height, min. connector information input connector j100 ground (fg) dc output connector j300 pin 1) ac line pin 2) empty pin 3) ac neutral 0.25? faston tab term. 1,2,3: rtn term. 4,5,6: +vout mating connector: amp molex 640250-3 pins: 640252-2 mating connector: molex 190020001 mating connector: amp 640250-6 pins: 640252-2 data sheet ? 2012 sl power electronics corp. the i nformation and specifications contained herein are believed to be correct at the time of publication. however, sl power accepts no responsibility for consequences arising from reproduction errors or in accuracies. specifications are subject to change w ithout notice. [4] x 0.156 4 plcs mtg holes


▲Up To Search▲   

 
Price & Availability of CINT1200A2875K01

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X